The rugged TA model nuclear-qualified temperature switch was tested up to 33Mrad, making it an ideal choice for severe conditions. Specifically designed to HELB requirements, it is qualified by a combination of testing and analysis that includes thermal aging, irradiation, mechanical/electrical cycling, random multi-frequency, and sine beat.
- Ductile iron housing for HELB tested to 33 Mrad
- Threaded cover with a double environmental seal
- Vent connection provided if needed
- May be engineered to meet your specifications
- Temperature 40°F to 375°F
- Special ranges available
Compliant
- 10CFR50, Appendix B/10CFR21
- NQA-1-2015
- CSA B51 Part 1
- ANSI N45.2
Qualified by a Combination of Testing and Analysis
- IEEE-323-1974 & 1983
- IEEE-344-1975 & 1987
Audited by
- Nuclear Procurement Issues Committee (NUPIC)
- Nuclear Industry Assessment Committee (NIAC)
- Canadian Technical Standards & Safety Authority (TSSA) N285.0
- Tractebel Engineering SUEZ Certificate nr. 3696